科風PCM VGD-3000(220V) 3000VA/2100W 在線式/直立式 UPS不斷電系統
📋 科風PCM VGD-3000(220V) 3000VA/2100W 在線式/直立式 UPS不斷電系統 詳細規格說明
● 請注意,此機輸出入皆為220V 先鋒系列 Vanguard UPS ● ◎ 真實在線式技術提供全方位電源保護 ● ◎ 純正弦波輸出 , 總 ● • 諧波失真:(THD) 小於 3% ● ◎ 全數位化 CPU 微處理控制 ● ◎ 可直流啟動 , 充分發揮 UPS 緊急備用功能 ● ◎ 閃電及突波保護 ● ◎ 短路及過載保護 ● ◎ 智能電池電源管理 (ABM) ● ◎ 關機時電池可自動充電 以下為制式規格 此機為220V, Multi Functional LCD On ● Line UPS. 15 LCD Display: Easy viewing of UPS status from LCD panel including: O/P Voltage O/P Load (%) Battery Charge (%) O/P Frequency O/P Watt (W) Temperature (°C) I/P Voltage O/P VA Battery Pack Number I/P Frequency O/P Current (A) Rating (A) Battery Voltage Back Up Time (Min.) CPU Version 14 UPS parameter settings: O/P Voltage O/P Load (%) Battery Charge (%) O/P Frequency O/P Watt (W) Temperature (°C) I/P Voltage O/P VA Battery Pack Number I/P Frequency O/P Current (A) Rating (A) Battery Voltage Back Up Time (Min.) CPU Version Unique Design : ● Vanguard rack mount models come in different heights such as 1U, 2U, or 3U to meet different space demands. ● Vanguard rack mount now is available from 700VA up to 12KVA ● Vanguard 3U rack mount model is designed to be flexible and able to fit in different spaces. ● The control panel can be adjusted 90 degree around to accommodate the UPS installation direction (vertically or horizontally) (4K ~ 12K) ● The display panel can be remove from the front panel and attached to the back panel with a cable in order to provide the wired ● remote feature. (4K ~ 12K) ● different directions of insertion slots are designed to attached with display panel providing 2 different angels to suit in different space demands. FEATURES: Cold start function (DC power on) Lightning and surge protection Battery replacement warning Schedule shutdown & reboot Hot swappable battery by user Emergency Power Off function Battery remain time display LCD display front panel Optional SNMP Card slot Wide input voltage range Power factor correction Manual bypass setting Free run mode setting EMI/RFI noise filter Support USB communication Multiple language LCD display On line output voltage selected True on ● line technology provides all power protection Pure sine ● wave output with less than 3% THD Fully digitized microprocessor controlled Short Circuit and overload protection Advanced battery management (ABM) Automatic battery charge in UPS off mode Automatic diagnostics & battery check RS ● communication port with monitoring software Network/fax/modem surge protection History record of power failure events UPSMON plus software monitoring Extended back up time with battery pack Optional Extension battery pack Load segmentation receptacles controllable High efficiency mode selectable Fan speed auto control when loads varies Tower Model (With LCD Display) VGD ● VGD ● INPUT Capacity (VA) 2000VA 3000VA Capacity (W) 1400W 2100W Voltage 100V/110V/115V/120V/127V 208V/220V/230V/240V Voltage/Range Load Capacity Voltage/Range Load Capacity 60 ~ 69V 0 ~ 40% 120 ~ 139V 0 ~ 40% 70 ~ 79V 0 ~ 70% 140 ~ 159V 0 ~ 70% 80 ~ 144V 0 ~ 100% 160 ~ 276V 0 ~ 100% Frequency 50 / 60 Hz Auto Sensing OUTPUT Voltage (on battery) 100V, 110V, 120V, 127V or 208V, 220V, 230V, 240V +/ ● % (Selectable Output Voltage) Frequency (on battery) 50 / 60 Hz +/ ● % Transfer Time 0 ms Overload Recovery Auto transfer to UPS High Efficiency Mode (AC to AC) > 95 % Line Mode > 86% UPS Green Mode Energy saving function (No Load Shutdown) UPS Design Technology On ● Line / Fully digitized microprocessor controlled Output Wave Form Sinewave Harmonic Distortion Crest Factor 3 : 1 PROTECTION & FILTERING Surge Protection 120V (IEEE C62.41) / 230V (IEEEC61000 ● level 3) Overload Protection 125% for 1 minute and 150% for 10 seconds Short Circuit UPS output cut off immediately or input fuse protection SYSTEM DISPLAY / WARNING Visual Display (LED Model) UPS on(green), line ● mode(green), battery mode(yellow), bypass(yellow), fault(red) Visual Display (LCD Model) Input / output voltage, input / output frequency, on ● line mode, back up mode, battery capacity, load level Audible Alarm (Battery Back ● Up) Beep every 5 sec UPS Fault Continuous beeping sound and LCD display Communication RS ● Serial Port and USB BATTERY Type Sealed, maintenance ● free lead acid batteries DC Voltage (V) Battery (Tower ) 72V / 12V7AH x 6 72V / 12V9AH x 6 DC Voltage (V) Battery (1U) None DC Voltage (V) Battery (2U) 72V / 12V7.2AH x 6 72V / 12V9AH x 6 Typical Recharge Time to 90% Full 3 hours Management Self ● test, adjustable battery transfer points and alarm settings Battery Protection Cut off without draining any current when battery is low Cold Start (DC Start) YES Back Up Time (Tower Model) Full load = 6 mins Half load = 15 mins Full load = 4 mins Half load = 10 mins Back Up Time 19" Rack mount (Full Load) 6 mins 4 mins Back Up Time 19" Rack mount (Half Load) 15 mins 10 mins PHYSICAL Input lnlet NEMA 5 ● P ~ 5 ● P (120V) / IEC 320 (230V) Receptacles NEMA 5 ● (120V) / IEC 320 (230V) Total Receptacles (UPS+Surge / Surge Only) 12 (120V), 8 (230V) Tower Dimensions lnches mm (inch) W x D x H 225 x 425 x 360 (8.9" x 16.7" x 14.2") Net Weight kg (lb) Tower model 31.6 (68.4) 32.5 (71.5) Shipping Weight kg (lb) Tower Model 33.6 (73.9) 35.5 (78.1) ENVIRONMENT Operating Temperature 0 ● deg C / 32 ~ 104 deg F Storage Temperature ● ~ 50 deg C / ● ~ 122 deg F Audible Noise (1 meter from surface) Relative Humidity 0 ~ 95% humidity, non ● condensing CONFORMANCE Safety UL 1778(120V), CE LVD (230V) EMC (EMS / EMI) IEC 61000 ● , FCC Part 15(120V), CISPR 22 (230V) Warranty policy Warranty policy may vary depends on region ● ※ 以上規格資料若有任何錯誤,以原廠所公佈資料為準。 警語 : 一般通路及網路直接販賣給使用者 , 需技術人員安裝 .