科風PCM VGD-1500(220V) 1500VA/1050W 在線式/直立式 UPS不斷電系統
📋 科風PCM VGD-1500(220V) 1500VA/1050W 在線式/直立式 UPS不斷電系統 詳細規格說明
● 警語 : 一般通路及網路直接販賣給使用者 , 需技術人員安裝 . 請注意,此機輸出入電壓皆為220V 先鋒系列 Vanguard UPS ● ◎ 真實在線式技術提供全方位電源保護 ● ◎ 純正弦波輸出 , 總 ● • 諧波失真:(THD) 小於 3% ● ◎ 全數位化 CPU 微處理控制 ● ◎ 可直流啟動 , 充分發揮 UPS 緊急備用功能 ● ◎ 閃電及突波保護 ● ◎ 短路及過載保護 ● ◎ 智能電池電源管理 (ABM) ● ◎ 關機時電池可自動充電 Tower Model (With LCD Display) VGD ● VGD ● " Rack ● Mount Model VGD ● RM VGD ● RM INPUT Capacity (VA) 700VA 1000VA 1500VA Capacity (W) 490W 700W 1050W Voltage 100V/110V/115V/120V/127V 208V/220V/230V/240V Voltage/Range Load Capacity Voltage/Range Load Capacity 60 ~ 69V 0 ~ 40% 120 ~ 139V 0 ~ 40% 70 ~ 79V 0 ~ 70% 140 ~ 159V 0 ~ 70% 80 ~ 144V 0 ~ 100% 160 ~ 276V 0 ~ 100% Frequency 50 / 60 Hz Auto Sensing OUTPUT Voltage (on battery) 100V, 110V, 115V, 120V, 127V or 208V, 220V, 230V, 240V +/ ● % (Selectable Output Voltage) Frequency (on battery) 50 / 60 Hz +/ ● % Transfer Time 0 ms Overload Recovery Auto transfer to UPS High Efficiency Mode (AC to AC) > 92 % Line Mode > 86% UPS Green Mode Energy saving function (No Load Shutdown) UPS Design Technology On ● Line / Fully digitized microprocessor controlled Output Wave Form Sinewave Harmonic Distortion Crest Factor 3 : 1 PROTECTION & FILTERING Surge Protection 120V (IEEE C62.41) / 230V (IEEEC61000 ● level 3) Overload Protection 125% for 1 minute and 150% for 10 seconds Short Circuit UPS output cut off immediately or input fuse / circuit breaker protection SYSTEM DISPLAY / WARNING Visual Display (LED Model) UPS on(green), line ● mode(green), battery mode(yellow), bypass(yellow), fault(red) Visual Display (LCD Model) Input / output voltage, input / output frequency, on ● line mode, back up mode, battery capacity, load level Audible Alarm (Battery Back ● Up) Beep every 5 sec UPS Fault Continuous beeping sound and LCD display Communication RS ● Serial Port and USB BATTERY Type Sealed, maintenance ● free lead acid batteries DC Voltage (V) Battery (Tower ) 24V / 12V7AH x 2 36V / 12V7AH x 3 36V / 12V9AH x 3 DC Voltage (V) Battery (1U) 24V / 6V7AH x 4 None DC Voltage (V) Battery (2U) 24V / 12V7AH x 2 36V / 12V7AH x 3 36V / 12V9AH x 3 Typical Recharge Time to 90% Full 4 hours Management Self ● test, adjustable battery transfer points and alarm settings Battery Protection Cut off without draining any current when battery is low Cold Start (DC Start) YES Back Up Time (Tower Model) 7 min Back Up Time 19" Rack mount (Full Load) 2U ● = 7 min, 1U = 7 min 2U ● = 7 min, 1U = 4 min 4 min Back Up Time 19" Rack mount (Half Load) 2U ● = 15 min, 1U = 15 min 2U ● = 15 min, 1U = 10 min 10 min PHYSICAL Input lnlet NEMA 5 ● P ~ 5 ● P(120V) / IEC 320 (230V) Receptacles NEMA 5 ● (120V) / IEC 320 (230V) Total Receptacles (UPS+Surge / Surge Only) 6 (120V), 4 (230V) Tower Dimensions lnches mm (inch) W x D x H 152 x 420 x 237 (6.0" x 16.5" x 9.3") Net Weight kg (lb) Tower model 13.9 (30.6) ● (37.6) 17.7 (38.9) Shipping Weight kg (lb) 15.6 (34.3) 18.9 (41.6) 19.5 (42.9) 19" Rack ● Mount Dimensions mm (inch) 428 x 525 x 44 (16.9" x 20.7" x 1.7") 1U None 428 x 425 x 84 (16.9" x 16.7" x 3.3") 2U Net Weight kg (lb) 19" rack mount 1U = 15.0 (33.0) 2U = 15.4 (33.9) 1U = 15.0 (33.0) 2U = 18.7 (41.4) 19.1 (42.0) Shipping Weight kg(lb) 19" rack mount 1U = 17.7 (38.9) 2U = 17.9 (39.4) 1U = 17.7 (38.9) 2U = 21.6 (47.5) 21.7 (47.7) ENVIRONMENT Operating Temperature 0 ● deg C / 32 ~ 104 deg F Storage Temperature ● ~ 50 deg C / ● ~ 122 deg F Audible Noise (1 meter from surface) Relative Humidity 0 ~ 95% humidity, non ● condensing CONFORMANCE Safety UL 1778(120V), CE LVD (230V) EMC (EMS / EMI) IEC 61000 ● , FCC Part 15(120V), CISPR 22 (230V) Warranty policy Warranty policy may vary depends on region ● ※ 以上規格資料若有任何錯誤,以原廠所公佈資料為準。